ATB Automation logo

Stöber SU6
Safety function for SI6 or SC6 servo drive

  • STO and SS1 (EN 61800-5-2) via PROFIsafe
  • PLe (Cat.4) according to EN ISO 13849-1
  • Integrated in SI6 or SC6 servo drive
SU6
SU6 dipsw
SU6 blok
SU6
safety blok SU6
SY6 STO signal flow
SY6 SS1 signal flow

The SU6 safety function is an extension of the SI6 or SC6 servo controller. With the SU6 option, the servo inverter can be included in the safety circuit as a safety related part of the control system (SRP / CS) for the redundant disconnection of the motor / actuator torque (STO).

The safety function has a two channel design. Both channels STOa and STOb are independent and must both be inactive in order to enable the motor torque (STO function not active). With the STO function active, the PWM signal to the power stage of the servo controller is switched off redundantly by the SY6 module so that the motor can no longer supply torque. In the case of SS1-t, the shutdown occurs after an adjustable period of time.

The safety functions STO and SS1 are operated via PROFINET (PROFIsafe).

SU6 is a fast and wear-free all-electronic solution. The safety module is designed in such a way that regular system tests can be eliminated. This prevents interruption of the operation of the controller and therefore the machine. In concrete terms, this means greater availability of machines and systems. The often complex planning and documentation of function tests is also eliminated.

 The SY6 safety module supports the Safe Torque Off (STO) and Safe Stop 1 (SS1-t) safety functions in accordance with EN 61800-5-2. The safety control (safety PLC) must activate both the STO and the SS1 output of the SI6 / SC6 servo inverter to allow the servomotor to deliver torque. If only one of the outputs is configured, the SI6 / SC6 servo inverter remains in a safe state (STO active).

The signal flow of the STO function according to stop category 0 in accordance with EN 60204-1 is shown in the diagram below.

SS1 corresponds to stop category 1 in accordance with EN 60204-1.

The SS1-t safety function ensures the time-controlled standstill of a motor with subsequent coupling-free status (STO is activated after a time delay), regardless of whether the motor has already come to a standstill.

The SS1 delay time T_SS1 is a safety-related parameter defined from the safety control (safety PLC).

The safety functions STO and SS1-t relate to the complete SI6 or SC6 module and are not asspecific. On dual axis controllers, both axles are brought into a safe state at the same time. An activated SS1 can not be interrupted.

  • Quick response, short lines
  • Renowned manufacturers
  • Profound product knowledge
  • High reliability

We supply slewing ring bearings, oscillating mountings, tensioner devices from stock and we also have spiral bevel gearboxes, servo gears and electromechanical actuators in our delivery program.


In addition we also select and offer the right components and systems for motion control solutions, such as servo gear motors, linear servo actuators and complete XYZ cartesian systems.

10
Jul
Roller screw actuator advantages

Roller Screw versus Ball Screw Actuators

In the ever-evolving field of engineering, roller screw technology has become a significant force in linear electric actuator motion control....

Read blog

Loading ...

Search

Loading ...